HEPA Filter for Ventilation and Air Conditioning System,Cleaning
Room
Structure:
Frame | Filter Media | Seperator | Sealant | Gasket | Safe guard |
Aluminum/Galvanised steel/Stainless steel | Micro Glass fiber paper | Continuous thermoplastic cord | Hot melt | EVA/EPDM | Color coated steel grid/Aluminum mesh |
Feature:
l Homogeneous filter media velocity coupled with low pressure drop
l Large surface area and high dust holding capacity
l Cost-efficient and dependable operation
l Light weight and easy to install
l Each filter element is tested for leakproofing before market
release
Application:
l Highly sensitive industrial processes (pharmaceuticals,
biotechnology, chemicals, food and beverages, optics,
micro-electronics, etc.)
l Sophisticated air-conditioning systems (theaters/intensive care
units in hospitals and medical institutes, sterile rooms, labs,
research centers, etc)
Technical data:
l H11/H13/H14/U15/U16 EN1822; DOP 99%@0.3micron, 99.99%@0.3micron,
99.999%@0.3micron, 99.9997%@0.12micron, 99.99997@0.12micron
l Recommended final pressure drop: 2-3 times initial pressure drop
l DIN 53438 Flammability: F1
l UL 900 Standard: Class 2
l Thermal Stability: 70celsius
l Moisture Resistance: 100% RH
Sample data:
HEPA data 1
W*H*D(mm) | Filter Class | Filter Area(m2) | Airflow/Intial Pressure Drop(CMH/Pa) | Airflow/Intial Pressure Drop(CMH/Pa) | Airflow/Intial Pressure Drop(CMH/Pa) |
305*610*50 | H13 | 3.88 | 235/115 | 300/135 | 570/275 |
H14 | 235/130 | 300/160 | 570/290 |
610*610*50 | H13 | 8.11 | 465/115 | 600/135 | 1130/275 |
H14 | 465/130 | 600/160 | 1130/290 |
1170*570*50 | H13 | 14.77 | 840/115 | 1080/135 | 2040/275 |
H14 | 840/130 | 1080/160 | 2040/290 |
1220*610*50 | H13 | 16.57 | 935/115 | 1205/135 | 2270/275 |
H14 | 935/130 | 1205/160 | 2270/290 |
305*610*70 | H13 | 5.23 | 235/85 | 300/110 | 570/210 |
H14 | 235/95 | 300/125 | 570/235 |
610*610*70 | H13 | 10.97 | 465/85 | 600/110 | 1130/210 |
H14 | 465/95 | 600/125 | 1130/235 |
1170*570*70 | H13 | 20.08 | 840/85 | 1080/110 | 2040/210 |
H14 | 840/95 | 1080/125 | 2040/235 |
1220*610*70 | H13 | 22.46 | 935/85 | 1205/110 | 2270/210 |
H14 | 935/95 | 1205/125 | 2270/235 |
ULPA data 2
W*H*D(mm) | Filter Class | Filter Area(m2) | Airflow/Intial Pressure Drop(CMH/Pa) | Airflow/Intial Pressure Drop(CMH/Pa) | Airflow/Intial Pressure Drop(CMH/Pa) |
305*610*50 | U15 | 3.88 | 235/135 | 300/170 | 570/320 |
U16 | 235/150 | 300/190 | 570/350 |
610*610*50 | U15 | 8.11 | 465/135 | 600/170 | 1130/320 |
U16 | 465/150 | 600/190 | 1130/350 |
1170*570*50 | U15 | 14.77 | 840/135 | 1080/170 | 2040/320 |
U16 | 840/150 | 1080/190 | 2040/350 |
1220*610*50 | U15 | 16.57 | 935/135 | 1205/170 | 2270/320 |
U16 | 935/150 | 1205/190 | 2270/350 |
305*610*70 | U15 | 5.23 | 235/115 | 300/110 | 570/210 |
U16 | 235/130 | 300/125 | 570/235 |
610*610*70 | U15 | 10.97 | 465/115 | 600/145 | 1130/290 |
U16 | 465/130 | 600/165 | 1130/310 |
1170*570*70 | U15 | 20.08 | 840/115 | 1080/145 | 2040/290 |
U16 | 840/130 | 1080/165 | 2040/310 |
1220*610*70 | U15 | 22.46 | 935/115 | 1205/145 | 2270/290 |
U16 | 935/130 | 1205/165 | 2270/310 |
Pleating machine for HEPA filter/V-bank filter and other ULPA
filters